COVID-19 Update - This is to inform you that the Government of India has announced a complete lockdown in India 22nd March 2020 to 14th April 2020. As a result, our offices will now be closed till 14th April 2020 and all our employees will be working from home. Office telephones will not be answered, and therefore you are requested to direct all your queries related to manuscript submission, review process, publication etc. at below mentioned details. editor@innovativepublication.com, rakesh.its@gmail.com, Mob. 8826373757, 8826859373, 9910947804

Article view: 383

Article download: 308

Indian Journal of Clinical Anaesthesia


Baska mask®-A third generation supraglottic airway device in clinical practice- A prospective observational study


Full Text PDF Share on Facebook Share on Twitter


Author Details : Anil Kumar M R, Sarika M Shetty*, Meghana Marulasidappa, Prashanth Parmar, Vyshnavi S

Volume : 5, Issue : 4, Year : 2018

Article Page : 576-581


Suggest article by email

Abstract

Introduction and Aim: Supraglottic airway devices are safer alternatives to endotracheal intubation during general anaesthesia. The recently introduced Baska mask is a third generation supraglottic airway device available now in India. As there are no studies about Baska mask published in India, this study was undertaken to evaluate the efficacy and safety of using the Baska mask in patients with no predictors of difficult airway.
Materials and Methods: Hundred patients belonging to American society of Anesthesiologists physical status class I and II with no predictors of difficult airway undergoing elective surgery under general anaesthesia were included for the study. The patients were classified as normal and overweight depending on the body mass index (<25>2 – normal and >25 kg/m2 - overweight). The ease of successfully securing the airway with the device was evaluated using the time, the number of attempts and ease of insertion. The correct placement was confirmed by fibre-optic assessment using the Brimacombe scoring system. The airway sealing pressure and leak fraction were estimated. Complications like airway trauma, sore throat, dysphagia and dysphonia were noted after removal. Statistical analysis was done using SPSS software version 22 and assessed by t-test and chi square test.
Results: Mean time of insertion was 9.7±1.9sec. In 97% (n=97) of patients the mask was placed successfully in the first attempt. Airway sealing pressure was 42.46±19.11 cmH2O and the leak fraction was 8.81±0.03%. Effective ventilation was present in all grades of Brimacombe scoring. Minimal postoperative airway trauma and sore throat were noticed.
Conclusions: Baska® mask is an effective supraglottic airway device which is easy to insert, provides good ventilation and has minimal complications.

Keywords: Supraglottic airway device, Baska mask, Airway sealing pressure, Leak fraction, Brimacombe scoring.

Doi : 10.18231/2394-4994.2018.0109

How to cite : Anil Kumar M R, Shetty S M, Marulasidappa M, Parmar P, Vyshnavi S, Baska mask®-A third generation supraglottic airway device in clinical practice- A prospective observational study. Indian J Clin Anaesth 2018;5(4):576-581

Copyright © 2018 by author(s) and Indian J Clin Anaesth. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (CC BY 4.0) (creativecommons.org)