COVID-19 Update - This is to inform you that the Government of India has announced a complete lockdown in India 22nd March 2020 to 14th April 2020. As a result, our offices will now be closed till 14th April 2020 and all our employees will be working from home. Office telephones will not be answered, and therefore you are requested to direct all your queries related to manuscript submission, review process, publication etc. at below mentioned details. editor@innovativepublication.com, rakesh.its@gmail.com, Mob. 8826373757, 8826859373, 9910947804

Article view: 359

Article download: 210

Indian Journal of Clinical Anaesthesia


Effect of dexmedetomidine on hemodynamic responses during tracheal extubation


Full Text PDF Share on Facebook Share on Twitter


Author Details : Meenal Agarwal, Anuradha Malliwal*

Volume : 6, Issue : 1, Year : 2020

Article Page : 23-29


Suggest article by email

Abstract

Introduction and Aims: Dexmedetomidine, an ?-2-adrenoreceptor agonist, offers excellent sedation without significant effect on respiratory or cardiovascular stability. It may be, thus, helpful to achieve smooth extubation.
This study was conducted to assess the efficacy of dexmedetomidine in attenuating hemodynamic responses and airway reflexes encountered during extubation.
Materials and Methods: Sixty ASA I & II patients, aged 18-50 years, undergoing elective surgery under general endotracheal anesthesia were enrolled for the study. They were assigned to two groups-1 and 2, of 30 patients each, in a randomized, double blind manner, to receive dexmedetomidine or normal saline (NS) intravenous infusion, respectively. Hemodynamic parameters (heart rate, systolic, diastolic and mean arterial pressures) were recorded at the time of starting the study drug infusion, during the infusion, at extubation and thereafter at specific intervals for 30 minutes. Quality of extubation was assessed on a 5-point scale; postoperative sedation assessed by Ramsay Sedation Scale. Any untoward occurrence like undue sedation, vomiting, hypotension, respiratory depression, laryngospasm, bronchospasm and desaturation was noted.
Results: Heart rate, systolic, diastolic and mean arterial pressures were significantly higher in Group 2 (p < 0>
Conclusion: Dexmedetomidine 0.5 mcg/kg infusion given over 10 minutes prior to extubation, decreases hemodynamic responses and results in smooth extubation.

Keywords : ?-2-adrenoreceptor agonist, Dexmedetomidine, General anesthesia, Extubation, Hemodynamics.

Doi : 10.18231/2394-4994.2019.0006

How to cite : Agarwal M, Malliwal A, Effect of dexmedetomidine on hemodynamic responses during tracheal extubation. Indian J Clin Anaesth 2020;6(1):23-29

Copyright © 2020 by author(s) and Indian J Clin Anaesth. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (CC BY 4.0) (creativecommons.org)