COVID-19 Update - This is to inform you that the Government of India has announced a complete lockdown in India 22nd March 2020 to 14th April 2020. As a result, our offices will now be closed till 14th April 2020 and all our employees will be working from home. Office telephones will not be answered, and therefore you are requested to direct all your queries related to manuscript submission, review process, publication etc. at below mentioned details. editor@innovativepublication.com, rakesh.its@gmail.com, Mob. 8826373757, 8826859373, 9910947804

Article view: 284

Article download: 159

Indian Journal of Clinical Anaesthesia


Simulator evaluation of the additional verification of intravenous drug (AVOID) -error system: A prospective randomized controlled study


Full Text PDF Share on Facebook Share on Twitter


Research Article

Author Details : Shazia Khan, Pamela Chia, Shariq Ali Khan*

Volume : 6, Issue : 2, Year : 2019

Article Page : 274-279


Suggest article by email

Abstract

Introduction: Medication errors occur in around 0.75% to 5% of all anaesthesia related medication administrations. We developed the “Additional verification of intravenous drug (AVOID) -error System” to reduce medication-errors in Anaesthesia and tested the effect of this system on drug-administration time and end-user acceptance in a simulated environment.
Materials and Methods: A randomized-controlled cross-over trial study on 20 anaesthesiologists from Singapore General Hospital was conducted in a simulated operating-room environment in September 2018. Participants were randomized to administer five 1 millilitre doses, from a prefilled pre-labelled syringe with and without the AVOID-error System, (intervention group and control group, respectively). The primary outcome recorded was time to complete a “drug administration”. Additionally, all study participants were individually asked to give an opinion about the effect of the AVOID-error system on workload, medication error reduction and willingness to use in their routine practice using a five-point Likert scale. A Paired t-test was used for inter-group comparison and statistical significance was defined as p < 0>
Results: Twenty Anaesthesiologists, (12 consultants and 8 trainees) with median 8.5 years (IQR, 3.75-22) of experience participated in the study. The mean time to complete a drug administration in the intervention and control groups were, 18.2 (SD ± 5.3) and 12.6(SD ± 3.8) seconds (p =0.001), respectively.
Conclusions: On an average, the use of the Avoid-error system increased the total drug-administration time by 5.6 (95% CI: 4.6 - 6.5) seconds.

Keywords: Human factors, Medical device, Medication error.

Doi : 10.18231/j.ijca.2019.051