COVID-19 Update - This is to inform you that the Government of India has announced a complete lockdown in India 22nd March 2020 to 3rd May 2020. As a result, our offices will now be closed till 3rd May 2020 and all our employees will be working from home. Office telephones will not be answered, and therefore you are requested to direct all your queries related to manuscript submission, review process, publication etc. at below mentioned details. editor@innovativepublication.com, rakesh.its@gmail.com, Mob. 8826373757, 8826859373, 9910947804


Print ISSN:-2394-2118

Online ISSN:-2394-2126

CODEN : IJCAGX

Current Issue

Year 2020

Volume: 7 , Issue: 1

Article Access statistics

Viewed: 637

Emailed: 0

PDF Downloaded: 203

Indian Journal of Clinical Anatomy and Physiology


Antenatal fetal age estimation by measuring Crown-Rump Length, Bi-Parietal Diameter and Femur Length


Full Text PDF Share on Facebook Share on Twitter


Author Details : Sarita Kumari, Padamjeet Panchal, Bheem Prasad

Volume : 4, Issue : 2, Year : 2017

Article Page : 208-211


Suggest article by email


Abstract

Introduction: The gestational age estimation is an essential part of the care and management of pregnant women. A number of methods have been used for fetal dating and ultrasonography have become as an integral part of Obstetrics. Objective of this study is to determine whether Ultrasonography (USG) based Expected date of delivery (EDD) is better or Last menstrual period (LMP) based EDD.
Materials and Method: This study was done on randomly selected 50 pregnant women. Cases were selected from those attending antenatal clinic, labour room, Indoor and outdoor of the Department of Obstetrics and Gynaecology, at medical college and hospital Kolkata. The parameters like Crown-Rump Length (CRL), Bi-parietal Diameter (BPD), and Femur Length (FL) were used to determine Gestational Age (GA) during 1st, 2nd and 3rd trimester with help of USG.
Result: The CRL was better parameter to determine GA in first trimester and BPD and FL was better parameters to determine GA in second and third trimester for gestational age estimation. The CRL, BPD and FL parameters together give the best assessment of GA in Uterus.
Conclusion: USG is a better diagnostic tool for estimation of EDD than the LMP method.

Keywords:
Bi-parietal Diameter, Crown-Rump Length, Femur Length, Gestational age, Pregnancy, Ultrasonography

How to cite : Kumari S, Panchal P, Prasad B, Antenatal fetal age estimation by measuring Crown-Rump Length, Bi-Parietal Diameter and Femur Length. Indian J Clin Anat Physiol 2017;4(2):208-211

Copyright © 2017 by author(s) and Indian J Clin Anat Physiol. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (CC-BY-NC 4.0) (creativecommons.org)