COVID-19 Update - This is to inform you that the Government of India has announced a complete lockdown in India 22nd March 2020 to 3rd May 2020. As a result, our offices will now be closed till 3rd May 2020 and all our employees will be working from home. Office telephones will not be answered, and therefore you are requested to direct all your queries related to manuscript submission, review process, publication etc. at below mentioned details. editor@innovativepublication.com, rakesh.its@gmail.com, Mob. 8826373757, 8826859373, 9910947804


Print ISSN:-2394-6369

Online ISSN:-2394-6377

CODEN : IJCBK6

Current Issue

Year 2020

Volume: 7 , Issue: 1

Article Access statistics

Viewed: 668

Emailed: 0

PDF Downloaded: 257

International Journal of Clinical Biochemistry and Research


A comparative study of blood glucose level measurement between glucometer and semi autoanalyser


Full Text PDF Share on Facebook Share on Twitter


Author Details : N.V. Lakshmi, P. Kiranmai

Volume : 5, Issue : 3, Year : 2018

Article Page : 423-426


Suggest article by email


Abstract

Introduction: There is a direct relationship between glycemic control and risk of systemic complications leading to high morbidity and mortality in diabetes.3 Estimation of blood glucose is the main investigation for the diagnosis and management of diabetes mellitus and also for monitoring emergency complications of DM. Glucometers are used for monitoring blood glucose levels in most of the hospitals. There is a need for establishing the reliability of results of glucometer as they also have limitations.6 Our study is undertaken to compare the glucose levels in capillary whole blood by glucometer and glucose levels in venous plasma samples by semi autoanalyser.
Materials and Methods: Study was conducted in the department of Biochemistry Osmania General Hospital. 50 Subjects both male and female in the age group of 25 to 65yrs attending out patient department of Medicine at Osmania General Hospital were included in the study. Capillary blood glucose is measured with a glucometer and venous plasma sample glucose is measured with a semi autoanalyser. Statistical analysis is done by mean comparison and student t test.
Results: When the two means are compared there is increase in the blood glucose levels measured by using a glucometer (117.76+39.01) when compared to venous blood samples levels measured by using a semi autoanalyzer (108.78+39.05) but there is no statistical significance (P> 0.05). Results showed a variation of 2% to 15% in individual subjects between the blood glucose levels by two methods.
Conclusion: Mean glucose levels in capillary blood sample estimated by glucometer is higher than the mean glucose levels in venous plasma samples estimated by semi autoanalyser, but there is no statistical significance. Hence glucometer can be used at bedside as a better alternative for out patient department diagnosis and in emergency situations.

Keywords: Glucometer, Semi auto analyser, Blood glucose.

Doi : 10.18231/2394-6377.2018.0089

How to cite : Lakshmi N, Kiranmai P, A comparative study of blood glucose level measurement between glucometer and semi autoanalyser. Int J Clin Biochem Res 2018;5(3):423-426

Copyright © 2018 by author(s) and Int J Clin Biochem Res. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (CC-BY-NC 4.0) (creativecommons.org)