COVID-19 Update - This is to inform you that the Government of India has announced a complete lockdown in India 22nd March 2020 to 14th April 2020. As a result, our offices will now be closed till 14th April 2020 and all our employees will be working from home. Office telephones will not be answered, and therefore you are requested to direct all your queries related to manuscript submission, review process, publication etc. at below mentioned details. editor@innovativepublication.com, rakesh.its@gmail.com, Mob. 8826373757, 8826859373, 9910947804

Article view: 259

Article download: 84

Indian Journal of Clinical and Experimental Ophthalmology


Comparison of accuracy of haigis and SRK II formula for intraocular lens power calculation in eyes with short axial length


Full Text PDF Share on Facebook Share on Twitter


Research Article

Author Details : Mohan Kumar H, Sangeetha T, Kanthamani , Nithiya Joe Babu*

Volume : 5, Issue : 3, Year : 2019

Article Page : 376-381


Suggest article by email


Abstract

Introduction: This study aimed to measure the postoperative residual spherical error and to find the correlation between the axial length and anterior chamber depth measured preoperatively with the postoperative refractive status.
Materials and Methods: A total of 174 patients of the age group 40-70 years axial length ? 22 mm undergoing cataract surgery were included in our prospective study in which the accuracy of SRK II was compared with Haigis formula. The participants were divided into group A and B by simple randomization technique. The subjects under group A were implanted with IOL calculated using Haigis formula and those under group B with SRK II formula. They were evaluated for visual acuity and residual refractive error. The degree of emmetropia of the participants was analysed using above data.
Results: A total of 174 eyes were included in our study of which 64 (36.7%) were males and 110(63.2%) were females. The mean axial length was 21.47mm and the mean anterior chamber depth was 3.17mm. Significant differences were found between the spherical error calculated by SRK II formula and Haigis formula. The mean spherical error in group A with Haigis formula was - 0.36 (range 0 D to -1.5) meanwhile group B with SRK II formula had a mean spherical error of + 0.55 (range 0 to +2 D). The postoperative refraction of patients implanted with IOLs calculated using Haigis formula was closer to emmetropia.
Conclusion: It was found that in patients with short axial length, Haigis formula gave an accurate prediction of the IOL power compared to SRK II formula. Using Haigis formula led to a mild over correction leading to a slightly more myopic outcome while SRK II formula led to a mild under correction leading to a mild hypermetropic outcome.

Keywords: Formula, Haigis, IOL power calculations, SRK II, Short axial length.

Doi : 10.18231/j.ijceo.2019.090

How to cite : Mohan Kumar H, Sangeetha T, Kanthamani, Babu N J, Comparison of accuracy of haigis and SRK II formula for intraocular lens power calculation in eyes with short axial length. Indian J Clin Exp Ophthalmol 2019;5(3):376-381