COVID-19 Update - This is to inform you that the Government of India has announced a complete lockdown in India 22nd March 2020 to 14th April 2020. As a result, our offices will now be closed till 14th April 2020 and all our employees will be working from home. Office telephones will not be answered, and therefore you are requested to direct all your queries related to manuscript submission, review process, publication etc. at below mentioned details. editor@innovativepublication.com, rakesh.its@gmail.com, Mob. 8826373757, 8826859373, 9910947804

Article view: 580

Article download: 222

Indian Journal of Microbiology Research


Study of diagnostic efficacy of widal slide agglutination test against widal tube agglutination test in enteric fever


Full Text PDF Share on Facebook Share on Twitter


Author Details : Roshni Pranav Patel, Minalben Bharatkumar Trivedi

Volume : 4, Issue : 3, Year : 2017

Article Page : 267-269


Suggest article by email


Abstract

Introduction: Enteric fever is a major and persistent public health problem in India. The slide widal is most commonly performed rapid method to diagnose due to its convenience, but its results are required to be compare with more standardly established tube widal test for its actual diagnostic significance. This study aims to compare the result of slide widal test with tube widal test to ascertain any significant difference between two methods.
Materials and Method: The 100 pre-collected serum samples with widal test request were received for the study over the six months period. Comparison of slide widal agglutination test with tube widal agglutination was done considering tube widal as a standard.
Result: The slide widal agglutination test shows false positive result in 5.3% and 48.1% serum samples with S.typhi O antigen & S.typhi H antigen, respectively. The Positive Predictive Value of widal slide agglutination test for O antigen and H antigen is 94% and 52% respectively.
Conclusion: The slide widal agglutination test showed high false positive rate and low positive predictive value especially with S.typhi H antigen. Therefore, the result of slide widal agglutination needs to be confirmed by tube widal agglutination test.

Keywords:
Agglutination tests, Comparison, Slide, Tube, Widal test

How to cite : Patel R P, Trivedi M B, Study of diagnostic efficacy of widal slide agglutination test against widal tube agglutination test in enteric fever. Indian J Microbiol Res 2017;4(3):267-269

Copyright © 2017 by author(s) and Indian J Microbiol Res. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (CC BY 4.0) (creativecommons.org)