COVID-19 Update - This is to inform you that the Government of India has announced a complete lockdown in India 22nd March 2020 to 3rd May 2020. As a result, our offices will now be closed till 3rd May 2020 and all our employees will be working from home. Office telephones will not be answered, and therefore you are requested to direct all your queries related to manuscript submission, review process, publication etc. at below mentioned details. editor@innovativepublication.com, rakesh.its@gmail.com, Mob. 8826373757, 8826859373, 9910947804


Print ISSN:-2581-9356

Online ISSN:-2581-9364

CODEN : IIJOCV

Current Issue

Year 2020

Volume: 6 , Issue: 2

Article Access statistics

Viewed: 566

Emailed: 0

PDF Downloaded: 199

IP Indian Journal of Orthodontics and Dentofacial Research


Comparing the accuracy of direct versus a new technique of indirect bracket placement- A clinical trial


Full Text PDF Share on Facebook Share on Twitter


Author Details : Patil B C, Harshvardhan Reddy, Akash Kencha*, Spoorthy Obalapura, Vishwanath Patil

Volume : 4, Issue : 4, Year : 2018

Article Page : 176-181


Suggest article by email

Abstract

Introduction: Aim of the study was to compare the accuracy of bracket placement between direct and new indirect bonding technique in following aspects: (a) occluso-gingival bracket position (vertical) (b) mesio-distal bracket position (horizontal), (c) Angulation of brackets.
Materials and Methods: 10 patients were bonded with split-mouth approach. For each patient, two randomly selected opposite quadrants were used as indirect bonding quadrant and the other two as direct bonding quadrant drawing 20 samples. The occluso-gingival, mesio-distal bracket position accuracy in both direct and the new indirect bonding technique were measured using digital caliper and the angulations of brackets were measured with the help of photographs and surface protractor software.
Results: results showed statistical difference between direct and a new indirect bonding technique. Proving indirect bonding is more accurate than the direct bonding of braces.
Conclusion: There is difference between mean bracket placement errors for direct and indirect methods, the range of errors in the three directions assessed were greater for direct than indirect bracket placement. The magnitudes of the findings are of clinical relevance.

Keywords: Direct bonding, Indirect bonding, Surface protractor software.

 

Doi : 10.18231/2455-6785.2018.0035

How to cite : Patil B C, Reddy H , Kencha A , Obalapura S , Patil V, Comparing the accuracy of direct versus a new technique of indirect bracket placement- A clinical trial. IP Indian J Orthod Dentofacial Res 2018;4(4):176-181