COVID-19 Update - This is to inform you that the Government of India has announced a complete lockdown in India 22nd March 2020 to 3rd May 2020. As a result, our offices will now be closed till 3rd May 2020 and all our employees will be working from home. Office telephones will not be answered, and therefore you are requested to direct all your queries related to manuscript submission, review process, publication etc. at below mentioned details. editor@innovativepublication.com, rakesh.its@gmail.com, Mob. 8826373757, 8826859373, 9910947804


Print ISSN:-2394-2746

Online ISSN:-2394-2754

CODEN : IJOGCS

Current Issue

Year 2020

Volume: 7 , Issue: 1

Article Access statistics

Viewed: 625

Emailed: 0

PDF Downloaded: 194

Indian Journal of Obstetrics and Gynecology Research


Management of missing threads of IUCD


Full Text PDF Share on Facebook Share on Twitter


Author Details : GN Vasanthalakshmi, SR Subasri, Priyadharshini K

Volume : 4, Issue : 4, Year : 2017

Article Page : 416-419


Suggest article by email


Abstract

Introduction: Intra uterine contraceptive device is an effective, reversible and long term method of contraception. The device is made of poly ethylene which is impregnated with barium sulphate to render it radio opaque so that the presence or absence of the device in the pelvis can be easily detected by radiograph or ultrasound. Each device has nylon thread attached to its lower end and this thread protrudes through the cervical canal into vagina. It does not require replacement for long periods. IUCD s have rare but endangering side effects such as uterine perforation.(1) Missing IUCDs may be asymptomatic or present with symptoms. It could be intrauterine, partially embedded in the cavity or extrauterine. Nowadays due to advent of hystero laparoscopy, many of the cases of missing IUCD s are managed easily.(2)
Objective: To study the management of misplaced intra uterine device.
Materials and Method: It is a Retrospective observational study conducted at a tertiary care hospital from June 2015 to June 2017 for 2 years.
Results: In the review of 37 patients with missing IUCD threads, 12 (32.4%) were removed by simple curettage or using IUCD hook under ultrasound guidance, 21 (56.7%) were removed under hysteroscopic guidance, 1 (2.7%) was removed by laparoscopy and 3 (8.1%) were removed by laparotomy.
Conclusion: Most of post placental insertion of IUCD s were embedded into uterine myometrium or perforated the uterus and required either endoscopy or laparotomy for removal.
 
Keywords: Intra uterine contraceptive device, Missing threads

How to cite : Vasanthalakshmi G, Subasri S, Priyadharshini K, Management of missing threads of IUCD. Indian J Obstet Gynecol Res 2017;4(4):416-419

Copyright © 2017 by author(s) and Indian J Obstet Gynecol Res. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (CC-BY-NC 4.0) (creativecommons.org)