COVID-19 Update - This is to inform you that the Government of India has announced a complete lockdown in India 22nd March 2020 to 14th April 2020. As a result, our offices will now be closed till 14th April 2020 and all our employees will be working from home. Office telephones will not be answered, and therefore you are requested to direct all your queries related to manuscript submission, review process, publication etc. at below mentioned details. editor@innovativepublication.com, rakesh.its@gmail.com, Mob. 8826373757, 8826859373, 9910947804

Article view: 523

Article download: 189

Indian Journal of Orthopaedics Surgery


Evaluation of Implant Failure in Long Bones Fractures – A Retrospective Study


Full Text PDF Share on Facebook Share on Twitter


Author Details : Sunil Kumar, Dinesh Kumar, S.P.S. Gill, Pulkesh Singh, Manish Raj, Alok Gupta

Volume : 2, Issue : 1, Year : 2016

Article Page : 64-68


Suggest article by email


Abstract

Background: Variety of implant design and quality are available and being used by orthopaedic surgeon to restore anatomy and enhance healing process of fractured bone. At times implants fail to achieve desired out come in few cases and a repeat surgery is required. This study evaluates causes of implant failure in fracture long bones.
Methods: Retrospective study analyzing 53 patients with 66 long bone fractures with failed implants dividing them into plate, unlocked nails and locked nails group was performed at level – I trauma centre of tertiary level medical college in North India, during January 2011 to march 2014. After thorough clinico-radiological evaluation, results were analyzed.
Results:  Maximum implant failure occurred in 20-50 yrs of age. Lower limb long bone implant failure 48 (72.7%) was more common than upper limb long bones 18 (27.3%). In all three groups fatigue failure (39%) was most common followed by bending (27.2%), loosening (18.8%) and infection 15.5% was observed. Implants defer in design and quality from manufacturer to manufacturer. Surgeons had chosen implants according to their technical knowledge and surgical skills. Re-trauma and patient non-compliance with instructions was also important cause of implant failure.
Conclusion: Cause of implant failure is multi-factorial hence we recommend use of suitable design and quality implant to match fracture configuration with proper surgical techniques. Patient should be educated and followed up according to rehabilitation protocol to avoid disappointments.

Keywords;
Implant failures, Fatigue failure, Long bone fractures, Implant corrosion, Implant loosening

How to cite : Kumar S, Kumar D, Gill S, Singh P, Raj M, Gupta A, Evaluation of Implant Failure in Long Bones Fractures – A Retrospective Study. Indian J Orthop Surg 2016;2(1):64-68

Copyright © 2016 by author(s) and Indian J Orthop Surg. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (CC BY 4.0) (creativecommons.org)