COVID-19 Update - This is to inform you that the Government of India has announced a complete lockdown in India 22nd March 2020 to 14th April 2020. As a result, our offices will now be closed till 14th April 2020 and all our employees will be working from home. Office telephones will not be answered, and therefore you are requested to direct all your queries related to manuscript submission, review process, publication etc. at below mentioned details. editor@innovativepublication.com, rakesh.its@gmail.com, Mob. 8826373757, 8826859373, 9910947804

Article view: 717

Article download: 239

Indian Journal of Orthopaedics Surgery


Prospective study of distal tibia fracture with anterolateral plating by MIPPO technique


Full Text PDF Share on Facebook Share on Twitter


Author Details : Kosalaraman Padmanaban, Major Kamalanathan, Balamurugan Palaniswamy, Vivekanandan Ramasamy, Ajay Pau

Volume : 3, Issue : 2, Year : 2017

Article Page : 153-159


Suggest article by email


Abstract

Background: The management of distal Tibia fractures has been a great challenge to orthopaedic surgeons due to soft tissue damage, extensive comminution, intra-articular extension and lack of vascularity.
Materials and Methods: Twenty five adult patients treated by anterolateral 3.5mm distal Tibial LCP by MIPPO technique between December 2014 and July 2016 were included in the study. The radiological outcome was assessed by Tenny and Wiss score and the functional outcome by AOFAS scale.
Results: Of the 25 patients in the study, 18 were males and 7 were females. The mean age was 49.32 years (range: 21-75 years). The majority of cases were AO type 43A3 (36%). Complete fracture union was achieved by 21 weeks (14-30 weeks). At final follow up 18 fractures united with no angulation at fracture site while 1 united in valgus (<100) and 1 varus (<50) and 3 in sagittal angulation (<10º angulation in both) which were consistent with acceptable limits. The mean AOFAS score was 79.16 after 8 months, with 4 cases having excellent outcome, 14 good, 3 acceptable and 4 cases with bad outcome. The complications in this study were angular deformity 5(20%), Infection 4 (16%), non-union 2 (8%), implant breakage 1 (4%).
Conclusion: Anterolateral distal Tibial plating by MIPPO technique gives good functional and radiological outcome with advantage of minimal soft tissue dissection without stripping the periosteum and preventing subsequent devascularisation of fracture fragments but it requires a long learning curve. Thus we conclude that anterolateral distal Tibial locking plate is a good option for managing the distal Tibial fractures.

Keywords:
Distal Tibia fracture, Anterolateral Plating, Functional Outcome, MIPPO technique

How to cite : Padmanaban K, Kamalanathan M, Palaniswamy B, Ramasamy V, Pau A, Prospective study of distal tibia fracture with anterolateral plating by MIPPO technique. Indian J Orthop Surg 2017;3(2):153-159

Copyright © 2017 by author(s) and Indian J Orthop Surg. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (CC BY 4.0) (creativecommons.org)