COVID-19 Update - This is to inform you that the Government of India has announced a complete lockdown in India 22nd March 2020 to 14th April 2020. As a result, our offices will now be closed till 14th April 2020 and all our employees will be working from home. Office telephones will not be answered, and therefore you are requested to direct all your queries related to manuscript submission, review process, publication etc. at below mentioned details. editor@innovativepublication.com, rakesh.its@gmail.com, Mob. 8826373757, 8826859373, 9910947804

Article view: 489

Article download: 146

Indian Journal of Orthopaedics Surgery


Reliability of optoelectronics motion capture analysis in hip range of motion


Full Text PDF Share on Facebook Share on Twitter


Author Details : Dhammapal S. Bhamare, Rahul M. Salunkhe, Pinakin P. Ayare, Abhijeet Shroff, Sumeet Kumar

Volume : 3, Issue : 4, Year : 2017

Article Page : 394-397


Suggest article by email


Abstract

Purpose: The purpose of this study was to determine the reliability of optoelectronic motion capture analysis to determine the hip range of motion.
Materials and Methods: Fifteen recreationally active male participants (age 26.67 + 4.84 years). Measurement values were got by performing the optoelectronic motion capture analysis on subjects with sensors attached to their bodies. The Root mean square error (RMSE) was used to determine the accuracy of optoelectronic motion capture analysis values got by the assessors and it was compared with the standard hip range of motion.
Results: The Root mean square error of optoelectronic measurements of the hip range of motion was calculated in reference to standard values. The left sided external rotation showed the highest deviation from the standard values (26.57). Hip adduction measurements using optoelectronic motion capture analysis were least deviated from standards (right – 29.70 and left – 29.70).
Conclusion: The optoelectronic motion capture analysis is a reliable tool to calculate the hip range of motion. But, further well designed studies need to be done in order to eliminate the limitations found in our study.

Keywords: Optoelectronics, Hip, Range of Motion, Reliability

How to cite : Bhamare D S, Salunkhe R M, Ayare P P, Shroff A, Kumar S, Reliability of optoelectronics motion capture analysis in hip range of motion. Indian J Orthop Surg 2017;3(4):394-397