COVID-19 Update - This is to inform you that the Government of India has announced a complete lockdown in India 22nd March 2020 to 3rd May 2020. As a result, our offices will now be closed till 3rd May 2020 and all our employees will be working from home. Office telephones will not be answered, and therefore you are requested to direct all your queries related to manuscript submission, review process, publication etc. at below mentioned details. editor@innovativepublication.com, rakesh.its@gmail.com, Mob. 8826373757, 8826859373, 9910947804


Print ISSN:-2395-1354

Online ISSN:-2395-1362

CODEN : IJOSHC

Current Issue

Year 2020

Volume: 6 , Issue: 1

Article Access statistics

Viewed: 562

Emailed: 0

PDF Downloaded: 187

Indian Journal of Orthopaedics Surgery


Role of proximal femur locking plate in management of complex proximal femoral end fractures


Full Text PDF Share on Facebook Share on Twitter


Author Details : Hardip Singh Mann, Girish Sahni, Arvind Kumar, Anand Mohan

Volume : 4, Issue : 1, Year : 2018

Article Page : 65-68


Suggest article by email


Abstract

Introduction: To study the role of proximal trochanteric contoured plate in management of complex proximal femur end fractures.
Materials and Methods: A total of 30 cases 11 male and 19 female patients aged 19 to 90 years [Mean age 42] were included. Time duration of surgery, total amount of blood loss, hospital stay, mobilization and weight bearing, radiological assessment of union, complications and Harris Hip score were assessed at the end of 6 months.
Results: Mean duration of surgery was 72.18 mins, average blood loss was 283.75ml, average hospital stay was 13.75 days. Mean time for radiological union was 16.8 wks and Harris hip score was 84.6. Abductor lurch occurred in 4 cases.
Conclusion: Proximal Femoral Locking Compression Plate (PFLCP) provides stable fixation for fractures of proximal end of femur especially for lateral wall fracture because it provides stable fixation of lateral fragments and prevents lateral migration of proximal fragments.

Keywords: Proximal femur fractures, Proximal femur locking plate, Harris Hip Score.
MESH words: Proximal femur fracture, Internal fixation, Extramedullary devices

Doi : 10.18231/2395-1362.2018.0014

How to cite : Mann H S, Sahni G, Kumar A, Mohan A, Role of proximal femur locking plate in management of complex proximal femoral end fractures. Indian J Orthop Surg 2018;4(1):65-68

Copyright © 2018 by author(s) and Indian J Orthop Surg. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (CC-BY-NC 4.0) (creativecommons.org)