COVID-19 Update - This is to inform you that the Government of India has announced a complete lockdown in India 22nd March 2020 to 3rd May 2020. As a result, our offices will now be closed till 3rd May 2020 and all our employees will be working from home. Office telephones will not be answered, and therefore you are requested to direct all your queries related to manuscript submission, review process, publication etc. at below mentioned details. editor@innovativepublication.com, rakesh.its@gmail.com, Mob. 8826373757, 8826859373, 9910947804

Article Access statistics

Viewed: 583

Emailed: 0

PDF Downloaded: 171

IP International Journal of Periodontology and Implantology


A-Comparative evaluation of root surface roughness after the use of gracey curettes and piezo-surgery-driven root planning tip on root surface: An in-vitro study


Full Text PDF Share on Facebook Share on Twitter


Author Details : Kiran Suradkar*, Amit Chaudhari, Amita M Mali, Yogesh Khadtare, Prakash Vhatkar

Volume : 3, Issue : 3, Year : 2018

Article Page : 105-110


Suggest article by email

Abstract

Introduction and Objective: The ideal instrument for initial periodontal therapy should enable the removal of all extraneous substances from the root surfaces without any iatrogenic effects. Because of that the objective of this study is to analyses and to compare the root surface roughness after using Gracey curettes, and a piezosurgery driven root planning tip, using SEM scanning electron microscopy.
Aim: The aim of this study was to compare root surface characteristics following root planing with hand- instrument and piezo surgery driven root planning tip instruments.
Material and Methods: A2 mm, 2 mm interproximal root area of 20 teeth (n = 40 surfaces) was evaluated by scanning electron microscopy (·50 to ·1000 magnification). Teeth were randomly assigned to the following two groups: Gracey curettes with 20 vertical strokes; and a piezosurgery ultrasonic scaler in mode ROOT with a power of two. In each case the evaluation for root surface roughness before and after root planing and surface roughness using the Index ‘t’ test ‘p’ value was measured.
Result: SEM microscopy reviled, the mean preoperative surface roughness was 3.587 with a standard deviation of 0. 466. The samples were root planed by curettes (Gracey) and the mean post-operative surface roughness was 2.364 with a standard deviation of 0.345. The results show that there was average surface roughness reduction in group A, following root planing by curette instrument, with ‘t’ value of 6.670 and ‘p’ value of =0.0000129. The ‘p’ value was more than 0 .01.
Conclusions:Out of the two instruments, namely Gracey curette, and piezosurgery driven root planning tip, were effective in mechanical debridement of the root surface. The results favored the use of piezo surgery root planning tip to achieve a smooth, clean root surface; however, the use of piezo surgery instrument tip was more time consuming, which might limit its use in clinical practice. Further clinical studies are needed.

Keywords:Gracey curette, Periodontal disease, Root planning, scaling; Piezo root planning tips

Doi : 10.18231/2457-0087.2018.0023

How to cite : Suradkar K , Chaudhari A , Mali A M , Khadtare Y , Vhatkar P , A-Comparative evaluation of root surface roughness after the use of gracey curettes and piezo-surgery-driven root planning tip on root surface: An in-vitro study. IP Int J Periodontol Implantol 2018;3(3):105-110

Copyright © 2018 by author(s) and IP Int J Periodontol Implantol. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (CC-BY-NC 4.0) (creativecommons.org)