COVID-19 Update - This is to inform you that the Government of India has announced a complete lockdown in India 22nd March 2020 to 3rd May 2020. As a result, our offices will now be closed till 3rd May 2020 and all our employees will be working from home. Office telephones will not be answered, and therefore you are requested to direct all your queries related to manuscript submission, review process, publication etc. at below mentioned details. editor@innovativepublication.com, rakesh.its@gmail.com, Mob. 8826373757, 8826859373, 9910947804

Article Access statistics

Viewed: 263

Emailed: 0

PDF Downloaded: 108

IP International Journal of Periodontology and Implantology


Scanning electron microscopic (SEM) comparison of dentinal tubule occlusion effected by a dentifrice containing NovaMin to that of diode laser (810nm)


Full Text PDF Share on Facebook Share on Twitter


Research Article

Author Details : Abhilash Antony, Jacob Varghese, Shibu Godfrey Pereira, Baiju R.M*, Raseena Beevi N

Volume : 4, Issue : 2, Year : 2019

Article Page : 48-52


Suggest article by email

Abstract

Introduction: Dentin hypersensitivity (DH) due to exposed dentine is common among periodontitis patients. The present study compares & evaluates the dentinal tubule occlusion achieved with NovaMin® containing dentifrice & 810 nm diode laser by means of SEM.
Materials and Methods: Sixty human premolar dentin discs of 2mm thickness were sanded with wet 600-grit carborundum paper and treated with 17% EDTA. Specimens were allotted to three groups of twenty each: Group 1- Control group, Group 2 –NovaMin® containing dentifrice application, Group 3 - lased with 810 nm diode laser. The proportion of completely occluded tubules and of partially occluded tubules to the total tubules (CO/TT & PO/TT) in the three groups were calculated, and analyzed.
Results: Both NovaMin® and Laser demonstrated more complete and partial occlusion of tubules than control group. The incidence of complete occlusion was more with NovaMin®, but that of partial occlusion was similar to diode laser group.
Conclusions: Although dentinal tubules occlusion was effective by both NovaMin®& diode laser (810 nm), NovaMin® produced a more complete occlusion of dentinal tubules.

Keywords: Dentin hypersensitivity, Diode laser, Dentinal tubule occlusion, Scanning electron microscope.

Doi : 10.18231/j.ijpi.2019.010

How to cite : Antony A, Varghese J, Pereira S G, R.m B, Raseena Beevi N, Scanning electron microscopic (SEM) comparison of dentinal tubule occlusion effected by a dentifrice containing NovaMin to that of diode laser (810nm). IP Int J Periodontol Implantol 2019;4(2):48-52

Copyright © 2019 by author(s) and IP Int J Periodontol Implantol. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (CC-BY-NC 4.0) (creativecommons.org)