COVID-19 Update - This is to inform you that the Government of India has announced a complete lockdown in India 22nd March 2020 to 3rd May 2020. As a result, our offices will now be closed till 3rd May 2020 and all our employees will be working from home. Office telephones will not be answered, and therefore you are requested to direct all your queries related to manuscript submission, review process, publication etc. at below mentioned details. editor@innovativepublication.com, rakesh.its@gmail.com, Mob. 8826373757, 8826859373, 9910947804

Covid Alert


Print ISSN:-2394-6784

Online ISSN:-2394-6792

CODEN : IJPOF3

Current Issue

Year 2020

Volume: 7 , Issue: 2

Article Access statistics

Viewed: 595

Emailed: 0

PDF Downloaded: 190

Indian Journal of Pathology and Oncology


Impact of head and neck intensity modulated radiation therapy on CT numbers of primary and nodal Gross tumour volume


Full Text PDF Share on Facebook Share on Twitter


Author Details : Athiyamaan MS, Hasib AG, Sridhar CH, Sudhir Prabhu

Volume : 4, Issue : 4, Year : 2017

Article Page : 483-488


Suggest article by email


Abstract

Introduction: CT number (CTN) for the gross tumour volumes (GTV) can change with radiation therapy which could be an early indicator for radiation response. This study investigates the correlation of radiation induced changes in volume and CTN in GTV of primary and nodal tumour during the course of intensity modulated radiation therapy (IMRT) in head and neck cancers (HNC).
Materials and Method: Re-CT scans were acquired at 4 weeks for 71 patients with stage II- IVb HNC treated with chemoradiation. The changes in volumes and CTN of the GTV primary and GTV node at 4 weeks of radiation were observed. Pearsons’s correlation were used to assess any correlation between CTN change and volume reduction of the GTVs.
Results: The volumes of the GTV Primary and GTV Node were reduced during the course of the radiation therapy after 4 weeks with mean volume shrinkage of 26.30±7.66(p<0.0001) and 32.09±37.2(p<0.04) respectively and the mean CTN reduced by 2.50±5.4 and 1.79±4.12HU’s respectively. The CTN and GTV volume decreases were found to be positively correlated (GTVP >GTV N) though the relationship is weak.
Conclusion: The CTN changes in GTV P and GTV N during delivery of radiation for HNC is measurable and are patient specific. The volume reduction is observed more in GTV N where as CTN reduction is noticed in both GTVs with a reasonable correlation between the mean CTN and volume reductions in GTVs.

Keywords: Head and neck cancer, CT number change, IMRT, Gross tumour volume

How to cite : Athiyamaan Ms, Hasib Ag, Sridhar Ch, Prabhu S, Impact of head and neck intensity modulated radiation therapy on CT numbers of primary and nodal Gross tumour volume. Indian J Pathol Oncol 2017;4(4):483-488