COVID-19 Update - This is to inform you that the Government of India has announced a complete lockdown in India 22nd March 2020 to 3rd May 2020. As a result, our offices will now be closed till 3rd May 2020 and all our employees will be working from home. Office telephones will not be answered, and therefore you are requested to direct all your queries related to manuscript submission, review process, publication etc. at below mentioned details. editor@innovativepublication.com, rakesh.its@gmail.com, Mob. 8826373757, 8826859373, 9910947804


Print ISSN:-2320-7302

Online ISSN:-2393-9834

CODEN : JDSOCI

Current Issue

Year 2019

Volume: 7 , Issue: 2

Article Access statistics

Viewed: 1469

Emailed: 0

PDF Downloaded: 191

Journal of Dental Specialities


3-D locking titanium miniplates in management of mandibular fracture; A prospective 64-67 clinical study


Full Text PDF Share on Facebook Share on Twitter


Author Details : Yadav S, Agarwal A, Singh S, Kumar S, Anand KR, Chhabra V

Volume : 3, Issue : 1, Year : 2015

Article Page : 64-67


Suggest article by email

Abstract

Purpose: The aim of this follow up clinical study was to evaluate the effectiveness of 2mm, 3-dimentional locking titanium miniplates.
Patients and Method: A prospective randomized clinical trial was carried out on 10 patients with mandibular fractures. The patients were evaluated for the operating time, clinical assessment of mobility after fixation, occlusion, adequacy of reduction on post-operative radiograph and any surgical complications. The statistical analysis was carried out in SPSS software.
Results: In 10 patients, 9(90%) were males and 1(10%) were females with a mean age of 28.75 years. Road traffic accident (RTA) was the etiological factor in 7(70%), inter-personal violence in 2 (20%) and fall in 1(10%) patient. The average intra-operative time was 40.10 min locking plates. This was found to be statistically significant when compared to the intra-operative time of non-locking plates in the literature. Bite force was measured in kilogram/cm2 using indigenously designed bite force measurement device. All the measurements were compared to the control group who did not sustain mandible fracture. At third month it was found that there was no significant difference in the bite between locking plates and control group. On examination satisfactory postoperative functional occlusion was found to be 100% in locking plates.
Conclusions: The results obtained suggest that 3-D locking plate/screw system fulfill the treatment goals of adequate reduction, fixation and stabilization of fracture of mandible. 3-D locking plating system adequately reduces the fracture without much need for adaptation and hence reduces the intra-operative time.

Keywords:
3-D locking miniplate, Mandibular fracture.

How to cite : Yadav S, Agarwal A, Singh S, Kumar S, Anand Kr, Chhabra V, 3-D locking titanium miniplates in management of mandibular fracture; A prospective 64-67 clinical study. J Dent Spec 2015;3(1):64-67