COVID-19 Update - This is to inform you that the Government of India has announced a complete lockdown in India 22nd March 2020 to 14th April 2020. As a result, our offices will now be closed till 14th April 2020 and all our employees will be working from home. Office telephones will not be answered, and therefore you are requested to direct all your queries related to manuscript submission, review process, publication etc. at below mentioned details. editor@innovativepublication.com, rakesh.its@gmail.com, Mob. 8826373757, 8826859373, 9910947804

Article view: 373

Article download: 173

Journal of Pharmaceutical and Biological Sciences


Periapical radiographic technique errors made with digital sensors


Full Text PDF Share on Facebook Share on Twitter


Author Details : Victória Conterato Dias, Aline Rose Cantarelli Morosolli, Maria Ivete Bolzan Rockenbach

Volume : 6, Issue : 3, Year : 2018

Article Page : 90-95


Suggest article by email

Abstract

Purpose: The objective of this study was to analyze the errors of technique in periapical radiographs as performed by fourth year students at the Dentistry School of the Pontifical Catholic University of Rio Grande do Sul, Brazil.
Material and Methods: Fifteen students were randomly selected and each one performed a complete periapical examination in a mannequin. A Direct Digital X-Ray System equipped with a size 2 Sensor was used to obtain the radiographic images. A total of 210 periapical radiographs were evaluated and the images were classified according to the errors that were related to the radiographic technique. The students were also asked to report on their experience with the direct digital system.
Results: The absence of a safety margin was the most frequent error on the radiographs that were performed by the students, while elongated image errors were not found. Regarding the radiographed regions, the highest frequency of errors was found in the upper canine region on the left side.
Conclusion: The need for a greater training of the students of dentistry, in order to better perform the radiographic technique and to decrease the occurrence of technique errors in periapical radiographs when using a digital receptor, is emphasized.

Keywords:Digital radiography, Diagnostic imaging, Learning, Students.

Doi : 10.18231/2320-1924.2018.0020

How to cite : Dias V C, Morosolli A R C, Rockenbach M I B, Periapical radiographic technique errors made with digital sensors. J Pharm Biol Sci 2018;6(3):90-95

Copyright © 2018 by author(s) and J Pharm Biol Sci. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (CC BY 4.0) (creativecommons.org)